ZNW-4000 Fluorescent Magnetic Particle Inspection Machine
Min.Order : 15 Pieces Quick Quotation >
Item Details
Product Description
Main technical index
Circumferential magnetization current AC:0-4000A can be adjusted continuously, with power outages a phase control (no misses).
Longitudinal magnetization MMF AC:0-16000AT continuously adjustable, with power outages-phase control (no misses).
Electrode gap: 0-3200mm.
Magnetic principle: power is present, the coil method.
Magnetizing method: circumferential magnetization, magnetization three longitudinal magnetization, composite can be used flexibly.
Environment:-10 ?-+ 40 ?, humidity = 80%.
Storage environment: temperature:-20 ?-60 ?, relative humidity is less than 70%. No corrosive gases, dust and strong high-frequency electromagnetic pollution.
UV intensity: from a 380mm UV intensity less than 1000 µg W/cm2.
Sensitivity test: People's Republic of China mechanical industry standard JB/T6065-92 standard of magnetic particle inspection of the specimen stipulated that standard a type specimen, 2nd test, show clear.
Power supply: three-phase four-wire, 380V ±10 v, 200A.
Check: the cracks and other defects on the surface of all.
Automatic demagnetization demagnetization AC:16000-0AT attenuation.
Payment & Shipping